Description:The FISCHERSCOPE X-RAY XDL instruments are universally applicable energy dispersive x-ray spectrometers. FISCHERSCOPE® X-RAY XDL® 210 FISCHERSCOPE® X-RAY XDL® 220 FISCHERSCOPE® X-RAY XDL® 230 FISCHERSCOPE® X-RAY XDL® 240 X-Ray Fluorescence Measuring Instrument for Manual or Automated Coating Thickness Measurements on Protective and Decorative Coatings, Mass-Produced Parts and Printed Circuit Boards. With the XDLM models, the X-ray source. The FISCHERSCOPE® X-RAY XDL® and XDLM® X-ray fluorescence (XRF) spectrometers are closely related to the XUL series. 12 mm; Travel: 230 mm in the standard version (optionally expandable to 620 or 1000 mm) Video camera for optical observation of the measurement location along the axis of the primary X-ray beam.

The XDLM 231 has a plane support stage, the XDLM 232 a manually operable X/Y stage. fischerscope x-ray xdlHelmut Fischer GmbH Institut für Elektronik und Messtechnik, 71069 Sindelfingen, Germany, Tel. The FISCHERSCOPE X-RAY XDL and fischerscope x-ray 231 manual XDLM series are closely related to the XUL and XULM series: Both use the same detectors, apertures and filter combinations. com Coating Thickness Material Analysis Microhardness Material Testing Sample Stage XDLM 231 XDLM 232 XDLM 237 Design fischerscope x-ray 231 manual Fixed sample support Manual XY-stage Programmable, motor-. Also for: Fischerscope x-ray xdlm 232, Fischerscope x-ray xdlm 237. 1 The X-ray Fluorescence Analyzer is a Rlgaku 3064 sequential spectrometer with a Model 3065, 108 position sample changer. Excellent ergonomics, easy operation, and fast calculation and data presentation, are all features of the XAN 120, as well as the entire FISCHERSCOPE X-RAY family. Product Code: XAN 250 Availability: In Stock.

X-ray fluorescence spectrometer with a programmable X/Y-stage and Z-axis for automated measurements of thin coatings and for materials analysis. X-Ray standards DIN ISO 3497 and ASTM B 568 Approval Fully protected instrument with type approval according to German radiation protection law Order FISCHERSCOPE X-RAY XDAL 237 •Version PIN detector•Version SDD 20 mm•Version SDD 50 mmandorder both numbers together). It constitutes the next step in the development of the proven FISCHERSCOPE X-RAY XDAL. 00 Ex Tax: ,789. View and Download FISCHER FISCHERSCOPE X-RAY XDLM 231 operator&39;s manual online. Functional Principle of a FISCHERSCOPE ® X-Ray Fluorescence Spectroscopy (XRF) Instrument. Adapter for smaller containers and cassettes are available on request Robot Reliable 4-axis, servo driven precision robot End effector. FISCHERSCOPE® X-RAY XDV®-μ 2 Description The FISCHERSCOPE X-RAY XDV-μ is a universally applicable energy-dispersive x-ray measuring instrument.

This generates the primary X-radiation. However, for the purpose of this manual, radiation refers to invisible waves or particles of energy from radioactive sources or X-ray tubes. , de Fischer Instrumentation (GB) Ltd, Lymington/Hampshire SO41 8JD, England, Tel. FISCHERSCOPE® X-RAY Measurement Systems X-ray tube Primary filter Measurement result Proportional counter tube X-RAY Product Overview Open the catalog to page 6 It takes ingenuity and solid, continuous development to create robust and high-precision X-ray measuring instruments that work reliably in both laboratory and everyday industrial settings. . X-Ray Radiation Safety Manual 030. FISCHERSCOPE X-RAY XAN 250. Calibration Standards for FISCHERSCOPE® X-RAY Measuring Systems (XRF) Product code: 16838 State: Out of stock All FISCHERSCOPE® XRF measuring systems perform precise measurement results, even without calibration, due to the integrated fundamental parameter method.

Depending on the measurement system, individual fixed apertures or exchangeable multi-apertures are employed. The XAN® 120 is accurate, safe and easy to use, robust and maintenance free. Serial tests or measurements of coating thickness and element distribution are made simple with the fast, program-mable XY-stage. 0 4 What is Radiation? Timed Opening price 7,000 GBP. The second objective is to fischerscope x-ray 231 manual give you an idea of the capabilities of this type of analysis. 24 X-RAY Product Overview FISCHERSCOPE® X-RAY XDV®-SDD With its large and easily accessible measurement cham-ber, the XDV-SDD can accommodate flat, plane objects as well as larger specimens with complex shapes.

FISCHERSCOPE® X-RAY XDLM® www. section of the primary X-ray beam, creating a measure - ment spot with a pre-defined size, which allows precise adjustment of fischerscope x-ray 231 manual the size and shape of the X-ray beam to the specimen geometry. The term radiation is used with all forms of energy: light, X-rays, radar, microwaves, and more. Outstanding accuracy and long-term stability are characteristic s of all FISCHERSCOPE X-RAY systems. Thus, the XDL instruments are also outfitted with a standard X-ray tube and a fixed aperture that are very well suited for measurements on larger parts.

The FISCHERSCOPE X-RAY XDL and XDLM series are outfitted with a standard X-ray tube and a fixed aperture that are very well suited for measurements on larger parts. Accelerated by the applied high voltage to very high speeds, the electrons bombard the anode material. Universal high performance X-ray fluorescence (XRF. 2 Symbols and Conventions Used in the Manual The following symbols and conventions are used in this manual: The fact that the trademark characters ® and ™ may be missing does not indicate that a name is a free trademark. Like their predecessors, they are particularly well suited for non-destructive thickness measurements and analysis of thin. They all feature an electric Z-axis but differ in their different specimen support stage. x-ray fluorescence measuring instrument with a programmable xy-stage and z-axis for automated measurements of thin coatings and for material analysis -- fischerscope® x-ray xdal® 237.

You can learn to use the software using step-by-step tutorials or video. Proportional counter tube, Peltier-cooled Silicon PIN diode or silicon drift detector as X-ray detector; Aperture: 2-x exchangeable, Ø 0. FISCHERSCOPE X-RAY XDLM 231 analytical instruments pdf manual download.

Analytical Instruments FISCHER FISCHERSCOPE X-RAY XDLM 231 Operator&39;s Manual (236 pages) Summary of Contents for FISCHER FISCHERSCOPE X-RAY 4000 Series. With motor-driven axes (optional) and measurement direction from top to bottom, the measurement instruments from the XDL® range enable automated serial tests. Typical fields of. It is particularly suited for the analysis of precious metals and their alloys in composi-tion and coating thickness. The necessity for re-calibration is dramatically reduced, saving time and effort.

This Instrument Is a closed x-ray system. FISCHERSCOPE X-Ray XAN 120 is a modern tabletop x-ray spectrometer (EDXRF). .

0 DESCRIPTION OF. X-RAY EQUIPMENT 5. List your products or services on Engineering360. 2 Thm x-ray tube Is protected by an Interlock switch that prevents turn an of high volge, a nd thus x-rays, If the tube Is not in the machine. Indicates safety information referring to danger for per-sons and warnings regarding damage to the measuring. With the XDLM models, the X-ray source is a micro-focus tube that allows for measurements on small structures and a better excitation of the low radiation components.

The electrically heated cathode emits electrons. The FISCHERSCOPE®-X-RAY XDAL®237 is a universally applicable energy-dispersive x-ray spectrometer. In addition, the XAN ® 500 can do more than just measure on large parts. Order FISCHERSCOPE X-RAY XDAL 237 • Standard (PIN detector• Option SDDSpecial XDAL product modification and technical consultation on request. They represent the next step in the development of the proven FISCHERSCOPE X-RAY XDL-B model series.

For measurements on very small objects such as the. FISCHERSCOPE®X-RAY XDLM®231 FISCHERSCOPE®X-RAY XDLM®232 FISCHERSCOPE®X-RAY XDLM®237 X-ray fluorescence spectrometer for manual or automated coating thickness measurements and analyses on pc-boards, electronics components and mass- produced parts. The XDLM 237 is equipped with a motor-driven X/Y stage that. Across the globe, industry, research and science depend on the reliability and accuracy of this equip-ment. Today, with over 10,000 units in operation worldwide, the name FISCHERSCOPE X-RAY is synonymous with powerful, reliable and durable X-ray fluorescence meas-uring instruments. FISCHERSCOPE® X-RAY XAN® 215 2 Description The FISCHERSCOPE X-RAY XAN 215 is the cost-effective entry-level X-ray fluorescence measuring instrument for non-destructive analysis of jewelry, coins and precious metals. All the main components – such as the detector, X-ray tubes and filter combinations – are identical.

Fischerscope X-Ray Machine XDL-240, Calibrated 6th July, Serial Number:Comprising: X-Ray XDL 240 Measuring Head, Programmable Meas. x-ray fluorescence measuring instrument for manual or automated coating thickness measurements and analysis -- fischerscope® x-ray xdl® series Fischer Technology, Inc. It is optimized for fast, non-destructive analysis of jewelry, precious metals in general, yellow and white gold, platinum and silver, rhodium, coins and all jewelry alloys and coatings. X-Ray standards DIN ISO 3497 and ASTM B 568 Approval Fully protected instrument with type approval according to the German regulations „Deutsche Röntgenverordnung-RöV“.

6 FISCHERSCOPE® X-RAY XDV®-μ SEMI Overview FISCHERSCOPE X-RAY XDV-µ SEMI Handling Wafer feeding Up to 3 BOLTS-compatible load ports, suitable for various SEMI-standard 200/300mm wafer pods. It is particularly well suited for non-destructive analyses and measurements of coating thicknesses on very small components and structures, even with complex coating systems. home products & services datasheets x-ray fluorescence spectrometers fischer technology, inc.

The first is to provide guides to using handheld/portable X-Ray Fluorescence (XRF) in the non-destructive analysis of objects in situ. X-Ray standards DIN ISO 3497 and ASTM B 568 Approval Fully protected instrument with type approval according to German radiation protection law Order FISCHERSCOPE X-RAY XULFISCHERSCOPE X-RAY XULFISCHERSCOPE X-RAY XULMSpecial XUL product modification and technical consultation on requestA p r i. The FISCHERSCOPE ® X-RAY XAN ® 500 is the most versatile X-ray fl uorescence system available in the market.

But there is a significant difference: The XDL and XDLM devices measure from top to bottom. The X-ray tube generates the primary X-radiation. The FISCHERSCOPE X-RAY XDLM are designed as user-friendly bench-top instruments. Measurement methods available from Fischer include X-Ray fluorescence, beta backscatter, magnetic induction, eddy current, and coulometric measurement principles that are incorporated into hand-held and/or bench top models. As a handheld device, it is perfect for inspecting coatings on bulky parts like airplane parts, pipes or turbine blades in a running production line.